Load factor and energy cost: same power, different bill
Two machines with the same capacity can receive different bills. One that runs steadily all day and one that runs flat out for two hours consume the same energy yet pay differently.
What load factor is
Load factor is average load divided by peak load over a period. Running 250 kW for eight of twenty-four hours gives an average of 83.3 kW and a load factor of 33%.
A high load factor means the equipment is used evenly, so the fixed cost per kWh is lower. A low one means a large installation idles most of the time.
That is why demand charges attach to peak or contracted demand: the utility must hold capacity for the peak, and charges for it.
Computing the energy charge
Daily energy = real power × hours. 250 kW for eight hours is 2,000 kWh; a 22-day month is 44,000 kWh.
At 120 per kWh that is 5,280,000 a month. It scales with energy, so the only ways down are fewer hours or better efficiency.
The template splits this into four nodes: power × hours, × days, × price. Split up, you can see which input moves the bill most.
The value of a lower peak
The demand charge follows the peak, so a 10% lower peak is a 10% lower demand charge even with identical consumption.
Lowering the peak means spreading load over time — staggering equipment starts instead of switching everything on together. That is peak shaving.
The table holds consumption at 44,000 kWh and moves only the peak, at 8,320 per kW.
| Peak demand | Monthly energy | Energy charge | Demand charge | Total |
|---|---|---|---|---|
| 250 kW | 44,000 kWh | 5,280,000 | 2,080,000 | 7,360,000 |
| 290 kW (PF 0.86) | 44,000 kWh | 5,280,000 | 2,418,605 | 7,698,605 |
| 200 kW | 44,000 kWh | 5,280,000 | 1,664,000 | 6,944,000 |
Efficiency is not load factor
Efficiency is the share of input energy that becomes work. Load factor is how evenly the equipment is used over time. Different problems, different remedies.
Better efficiency does the same work with less power; a better load factor does more work with the same equipment. Cutting a bill needs both.
load_factor = average_load / peak_load
daily_kwh = P * hours_per_day
monthly_kwh = daily_kwh * working_days
energy_cost = monthly_kwh * price
demand_cost = peak_kw * demand_charge
What the model shows
Changing hours and working days moves the energy charge proportionally; the demand charge answers only to real power and power factor. Whichever is more sensitive is where the saving is.
Adding days raises consumption and lowers fixed cost per kWh while raising the total bill. A better load factor and a smaller bill are different goals; decide which one you want first.
Questions
Does a high load factor mean a cheaper bill?
It improves the unit cost, but the total grows with consumption. At a fixed consumption, lowering the peak is what cuts the demand charge.
Is load factor the same as power factor?
No. Power factor is real over apparent power due to phase difference; load factor is average over peak load over time. Different dimensions entirely.
Sources
Every calculation here can be reproduced with a template in the simulator.
Open the simulator