opyeb FlowSim

OPYEB · NODE GRAPH SIMULATOR

Don't spread the formula out.
Wire it into a graph.

FlowSim is a simulator that runs a calculation as a node graph. Place constants, sliders, series accumulators, operations, branches, sums and output nodes, connect them with wires, and a topological sort decides the order and recomputes. Four templates cover compounding and tax, SaaS cash flow, electrical load cost, and inventory with a queue; everything runs inside this browser.

Template

1 · Node graph

· Drag a node header to move· Output port → input port to wire· Click a wire to cut it· Click a node to edit its value· Scroll the canvas to see the whole graph

3 · Series chart

2 · Edit node

4 · Sensitivity

5 · Node values (topological order)

Values in the order the topological sort produced. Nodes inside a cycle are not computed.

#NodeTypeValueSeries

How it works

  1. 01Start from a template

    Pick wealth, SaaS, power or inventory and the nodes arrive wired. Move a slider and every dependent node is recomputed in topological order.

  2. 02Wire and edit

    Click an output port, then an input port on another node. A connection that would create a cycle is refused; nodes can be dragged, edited or deleted.

  3. 03Read results and sensitivity

    Check the output series by month or year, then shake each key input by ±20% and read the tornado chart to see which assumption moves the answer.

What is on one screen

Node-graph (DAG) canvas

Constant, slider, series (compounding) accumulator, operation (+ − × ÷ min max power tax fee), branch, sum and output-chart nodes. Drag nodes, click ports to wire, click a wire to cut it.

Topological recompute

Kahn's algorithm fixes the order from the wires and every node is computed exactly once. Change an input and the nodes that depend on it are recomputed immediately.

Cycle guard

A → B → C → A cannot be wired. Load a JSON that already contains a cycle and the computation stops with the offending nodes marked.

Sensitivity analysis

For the chosen output, each slider and constant is moved by −20% and +20%, the whole graph is recomputed, and the results are ranked in a tornado chart and a table.

Why draw the calculation

FlowSim has no server that computes for you. Nodes and wires live in page memory, and the topological sort and simulation run in JavaScript on your device. Network requests are limited to the page's own static files and the ad script that loads only on the real domain. There is no database of your numbers and no tool that reports usage.

The structure becomes visible

A formula full of =B4*(1+C2) hides which cell feeds which. A node graph shows what goes into what, so when a number looks wrong you know which input to doubt.

Order does not change the answer

A topological sort keeps only the dependencies. Moving nodes or adding new ones leaves the values unchanged; if the values change with the layout, the model has a cycle.

Assumptions can be shaken

Knowing that a 20% move in one variable shifts the result by 4% tells you which assumption deserves more research. That is the whole point of building the model.

Nothing is left behind

The graph lives in page memory. Saving happens only when you download the JSON, and the site never receives it. No account, no upload, no analytics.

Questions

Is the calculation really local?

Yes. There is no endpoint to send it to. Node values sit in page memory and moving a slider re-runs the sort and the simulation in place. Open the network panel and drag a slider: no new request appears.

Which nodes are available?

Constant, slider, series (compounding) accumulator, operation (+ − × ÷ min max power tax fee), branch (if), sum of up to four inputs, and an output-chart node. The series node applies an annual or monthly rate over a number of periods.

What happens with a cycle?

Before wiring, FlowSim checks whether the new edge would close a loop and refuses if it would. If you load a JSON that already contains a cycle, computation stops and the nodes in the loop are marked.

What does the sensitivity panel do?

It takes the selected output, moves each input variable to −20% and +20%, recomputes the whole graph, and ranks the impact. That shows which assumption actually drives the conclusion.

Can I save or share a graph?

Download it as JSON and keep or send the file; load the same format to continue where you left off. The site itself has no account and no server-side storage.

Can I rely on the numbers?

The arithmetic follows the formulas shown. Template rates, tariffs and prices are illustrative, so replace them with your own and check the assumptions before deciding anything. This is a calculator, not investment, tax or electrical engineering advice.

Guides

Fifteen guides on node graphs, topological order, compounding and tax, SaaS metrics, electricity cost, inventory and queues, and sensitivity analysis. Every example can be reproduced with a template here.

All guides

Start with one template

The wealth template arrives with compounding, tax and inflation already wired. Move a slider and the result and sensitivity update at once.

Open the wealth template